header healthcare 2

Liberty for healthcare

Liberty Zorg - Klimaattechniek

Our design for your benefit

As versatile and complex as the healthcare sector can be, the wishes and variations for air treatment can be diverse and specific as well. We can translate your wishes into technical solutions without compromising on quality by using our Liberty air handling units. 

A completely smooth PET inner wall, double hygienic (VDI 6022) sealing, maximum leak tightness (L1), 70 mm wall thickness and high corrosion resistance are basic properties that make our Liberty air handling units so suitable for the healthcare sector. 

PROJECT SPECIFIC SOLUTIONS
As versatile and complex as the healthcare sector can be, the wishes and variations for air treatment can be diverse and specific as well. We can translate your wishes into technical solutions without compromising on quality by using our Liberty air handling units.

About our medical air handling units

Our medical air handling units are often equipped with:

  • Twin coil heat recovery
  • Humidification sections
  • High-quality and specific filtration such as active carbon and Hepa
  • Empty sections for cleaning between components
  • Special hygiene drip trays in accordance with VDI 6022
  • Priva scheme that connects to the existing Priva Network

REALLY DURABLE
As versatile and complex as the healthcare sector can be, the wishes and variations concerning air treatment can be diverse and specific as well. We can translate your wishes into technical solutions without compromising on quality by using our Liberty air handling units.

DESIGNED FOR YOUR BENEFIT
A completely smooth PET inner wall, double hygienic (VDI 6022) sealing, maximum leak tightness (L1), 70 mm wall thickness and high corrosion resistance are basic properties that make our Liberty air handling units so suitable for the healthcare sector.

WE MAKE IT FIT
Our standard box sizes are suitable for air volumes from 1,000 m³/h to over 100,000 m³/h. We can take the available space on site into account in the design. If the air handling unit is too large to transport or install, we can also assemble it on location.

HYGIENIC DESIGN WITH LOW OPERATING COSTS

IN ACCORDANCE WITH VDI 6022

This German hygiene standard describes exactly what requirements an air handling unit must meet. The Liberty air handling units meet most requirements as standard and can be fully configured in accordance with VDI 6022 as desired.

The air treatment system is an important part of the entire package of measures aimed at infection prevention. In an operating department in which a certain pressure hierarchy is required to prevent post-operative wound infections and contamination by germs, stability of the air management, filter class and airtightness of the air treatment system is crucial. An ePM1≥90% filter that can be removed on the dirty side is the basic filter class and is usually supplemented with a HEPA filter in the duct or above the inlet grille. In addition to the high (hygienic) quality requirements, operating costs due to energy consumption and maintenance have a high priority in the selection of air treatment systems. We strive for the highest achievable hygiene through the right choice of materials, an ingenious design, and real craftsmanship during the production process.

SPECIFIC BENEFITS

  • Completely flat PET inner surface to ensure germs, such as MRSA, have virtually no chance.
  • Double durable hygienic sealing on panels and access hatches, with hygiene certificate and very low air leakage (L1).
  • Locks with overpressure protection concealed in the inspection hatch and style to ensure a smooth, hygienic inner wall (VDI 3803).
  • No chance of condensation and moisture formation in unwanted places due to high insulation values (T1/TB1).
  • Noise baffles with hygiene certificate (removable).
  • Removable filters on the dirty side.
  • High mechanical strength (D1) resulting in minimal deformation/leakage at high system pressure.
  • Application of high-quality corrosion-resistant materials (composite or stainless steel 316) and hygienic components.
  • Configurations with optimal accessibility or cleanability on both sides of the components are possible.
  • Cleaning/disinfecting with chlorine or hydrogen peroxide is possible.

Product features

RVS INOX 316 filterraam
INOX 316 filter window

 

Koudebrugvrije sloten
Cold bridge-free locks

 

Dampdicht paneel met dubbele afdichting
Vapour-tight panel with double sealing

Priva regelaar met bus-connectivity
Priva controller with bus connectivity

 

Vlakke composiet/PET binnenwand
Flat, composite PET inner wall

 

Composiet eenvoudig reinigbare lekbak
Composite, easy to clean drip tray

It will only takes 5 minutes of your time

Quotation tool

Are you looking for the correct dimensions and pricing for your air handling units? Try our new Quotation Tool version || and find the answer you’re looking for in just 5 minutes.

ipad liberty selectiontool